Beli rcbo schneider di monotaro.id
Kami Menampilkan Rekomendasi Kami Untuk Anda! Anda Bisa Membelinya Kapan Saja di monotaro.id
- Hager Combined MCB/RCD (RCBO)Deskripsi:Compact protection devices which provide MCB overcurrent protection and RCCB earth leakage protection in a single unit. Specification IEC 61009-1 Protected against transient voltages (lightning, line disturbances,..) and transient currents (from high capacitive circuits) Technical data : The units are available with current ratings of 6A, 10A, 16A, 20A, 25A, 32A and 40A. The device switches both the phase and neutral conductors. All ratings have 10mA, 30mA, 100mA or 300mA earth leakage protection. The units feature indicators which show whether tripping is due to an overcurrent or earth leakage fault. Mechanical life : -2.000 operations -6kA IEC 61 009-1 -10kA IEC 60 947-2 Connection capacity -Rigid conductor 25mm2 -Flexible conductor 16mm2atribut:
- Number of Poles: 2
- Breaking Capacity (kA): 6
- Voltage Rating (V): 127-230
- Current Rating (A): 6-40
- Schneider Electric RCBO Slim Domaeatribut:
- Number of Poles: 2P
- Earth-Leakage Sensitivity (mA): 30
- Breaking Capacity (kA): 6
- Rated Operational Voltage (V): 230 (AC)
- Frequency (Hz): 50/60
- Curve Code: C
- Magnetic Trip: 5-10xIn
- Trip Unit: Thermal-magnetic
- NIPPON VALQUA Gasket ToolDeskripsi:Support iron (300 mm), floating rod for needle core, floating rod for cutting blade, straight core needle, bending / extending core needle, blade, floating rod knob screw, floating rod straight top x 5, holding bolt for needle core, cutting blade holder Bolt, L-shaped handle, grindstoneatribut:
- Material: Case: Resin Jig Tool: Metal
- Cutting Diameter (mm): 50 to 540 (minimum 20 is possible by using a bending and stretching needle)
- Case Color: Yellow
- Hager Miniature Circuit Breakers 1-PoleDeskripsi:Connection capacity : - 35mm2 flexible wire (50mm2 possible with some cable end-caps) - 70mm2 rigid wire KEMA In conformity with the lEC 60 898-1, 947-2 approved Tripping curves : CIC” magnetic setting between 5 and 10 Inch “D” magnetic setting between 10 and 20 Inch
- Schneider Electric Spacial CRNatribut:
- Applications: Multi-Purpose
- Category: Compact Enclosure
- Range: Spacial
- Schneider Electric Acti 9 iPF & iPRD - Surge Arresteratribut:
- Operating Voltage Max Uc (V): 340
- Schneider Electric Domae MCB Miniature Circuit Breaker 1Patribut:
- Breaking Capacity (kA): 6
- Curve Code: C
- Rated Operational Voltage (V): 230
- Number of Poles: 1P
- Frequency (Hz): 50/60
- Magnetic Trip: 5~10 x In
- Mounting Mode: Clip-on
- Network Type: AC
- Trip Unit: Thermal-magnetic
- Hager Miniature Circuit Breakers 3-PoleDeskripsi:Connection capacity : 35mm2 flexible wire (50mm2 possible with some cable end-caps), 70mm2 rigid wire Tripping curves : C magnetic setting between 5 and 10inch KEMA -In conformity with the -IEC 60 898-1, 947-2 approved
- Schneider Electric Domae MCB Miniature Circuit Breaker 3Patribut:
- Number of Poles: 3P
- Breaking Capacity (kA): 6
- Rated Operational Voltage (V): 400 (AC)
- Curve Code: C
- Frequency (Hz): 50/60
- Magnetic Trip: 5-10xIn
- Trip Unit: Thermal-magnetic
- Legrand RCBO - DX3 6000 Type N Right Handatribut:
- Rated Voltage (V): 230
- Frequency (Hz): 50
- Number of Pole: 2 (total)
- IP Protection: IP20
- Built-in Depth (mm): 44
- Connectable Conductor Cross Section Solid Core (mm²): 0.75-16
- Flush-mounted Installation: Yes
- Number of Protected Poles: 1
- Pollution Degree: 2
- Width in Number of Modular Spacings: 2
- Schneider Electric TeSys Deca Electronic Relaysatribut:
- Separate Part Category: Connection accessory
- Device Short Name: LAD
- Legrand RCBO - DX3 6000 4 Modulesatribut:
- Breaker Type: AC
- Schneider Electric TeSys Deca Contacts set LA5-D Seriesatribut:
- Poles Description: 3P
- Product or Component Type: Main Contact Set
- Range: TeSys
- Schneider Electric Acti iID RCCBatribut:
- Product or Component Type: Residual Current Circuit Breaker (RCCB)
- Device Location in System: Outgoer
- Device Short Name: IID
- Product Name: Acti 9 iID
- Range: Acti 9
- Hager Auxiliaries and Accessories for MCBsARCCBsDeskripsi:All auxiliaries are common to both single and multi-pole circuit breakers. These auxiliaries are fitted to the left hand side of devices Fault indication, auxiliaries, shunt trips, and under-voltage releases are fitted with a flag indicator that indicates the automatic/remote ripping of the device. Test mode for CZ001, MZ201, MZ202 : possible to test cabling of auxiliary circuits operation by tripping-over contacts manually. Resetting of contact occurs simultaneously with MCB/RCCB resetting. CZ001 must be fitted on the RCCB before fitting maximum one additional auxiliary (MZ203 to MZ206). Up to 4 auxiliaries can be fitted on MCB.atribut:
- Isolating Voltage (V): 500
- ABB Arc Fault Detection Device Integrated with RCBODeskripsi:DS-ARC1 C6 A30 Arc fault detection device integrated with RCBODS-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated RCBO in three modules, for the protection against earth arc faults, parallel arc faults, series arc faults, overvolatge, short-circuit currents, overload, earth fault currentsatribut:
- Connecting Capacity (mm²): Busbar 10, Rigid 1-25, Flexible 1-25
- Built-in Depth (mm): 69
- Auxiliary Voltage AC/DC (V): 230
- Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Undervoltage release, Overvoltage release, Auxiliary contact for bottom fitting
- Actuator Type: Toggle - Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions
- Cable Size (mm²): 25
- Contact Position Indication: Red ON / Green OFF
- Dielectric Test Voltage (kV): 2.5
- Electrical Endurance (cycle): 10000
- Energy Limiting Class: 3
- Fault Indication: Blue flag on toggle
- Frequency (Hz): 50
- Housing Type: Insulation group I, RAL 7035
- Leakage Current Type: A
- Mechanical Endurance (cycle): 20000
- Mounting Position: Any
- Mounting Position of Accessories: Right
- Number of Poles: 2
- Number of Protected Poles: 1
- Hager KontaktorDeskripsi:Contactors Contactors are essential power devices to control heating, lighting or ventilation systems They are recommended in association with control and energy management devices (thermostats, delay timers, programmers...) Standard 11 and 2 D versions are recommended for applications where a reduced consumption and heating dissipation are needed. Complies with IEC 61095 The contactors can be associated with the auxiliary contact ESC080 for remote signaling. It is recommended to use a heat dissipation insert LZ060 between each 3 products.
Daftar Harga rcbo schneider Terbaru September 2025
Hager Combined MCB/RCD (RCBO) | Rp1.299.900 |
Schneider Electric RCBO Slim Domae | Rp559.900 |
NIPPON VALQUA Gasket Tool | Rp16.999.900 |
Hager Miniature Circuit Breakers 1-Pole | Rp61.000 |
Schneider Electric Spacial CRN | Rp129.900 |
Schneider Electric Acti 9 iPF & iPRD - Surge Arrester | Rp429.900 |
Schneider Electric Acti9 iEM3000 Series Current Transformer Tropicalised | Rp109.900 |
Schneider Electric Domae MCB Miniature Circuit Breaker 1P | Rp65.000 |
Hager Miniature Circuit Breakers 3-Pole | Rp249.900 |
Schneider Electric Domae MCB Miniature Circuit Breaker 3P | Rp229.900 |
Data diperbarui pada 04/09/2025 (Harga belum termasuk PPN)